Terminal de pesage PUE C32
This image is for reference only.

Terminal de pesage PUE C32

Code produit: WX-008-0141
close
Change the model:
Terminal de pesage PUE C32
Select all
Voir
Download
Description
Boîtier et afficheur
Le boîtier est en matière ABS. Terminal est équipé d’un afficheur graphique 5’’ en couleurs garantissant la lisibilité parfaite et d’un clavier à membrane avec 22 touches librement programmables. Le menu peut être adapté aux besoins terminal de l’opérateur. De plus, il permet le service facile et intuitif.

Alimentation optionnelle par un accumulateur
Grâce à l’installation optionnelle d’un accumulateur, terminal PUE C32 peut fonctionner dans des conditions d'alimentation instable ou de son absence complète.

Interfaces de communication
terminal est équipé des interfaces RS 322, USB-A, USB-B, Ethernet, 4×Entrée, 4×Sortie. Les interfaces rendent possible la coopération avec beaucoup d’appareils externes, p.ex. une imprimante, un ordinateur ainsi que l’échange de données à l’aide des clés USB.
La connexion de terminal avec les réseaux sans fil est possible grâce au module de communication sans fil intégré Wireless Connection.

Gestion de données
Dans les terminal PUE C32, le système d’information est basé sur 7 bases de données avec le nombre maximum d’enregistrements :
  • Produits - 15 000
  • Utilisateurs - 500
  • Recettes - 500
  • Emballages - 500
  • Clients - 500
  • Étiquettes - 500
  • Variables universelles – 100
Les bases de données peuvent être importées et exportées en utilisant les clés USB.

Mémoire ALIBI
La mémoire ALIBI utilisée est une zone de sécurité des données et permet d’enregistrer jusqu’à 500 000 enregistrements de pesage. Cela garantit la sécurité de la continuité de la collecte de données à long terme.
Paramètres Techniques
Afficheur

5” graphique couleurs

 

Dimensions d'appareil

206×140×71

 mm

Dimensions de colis

300×250×130

 mm

Masse nette

0,7

 kg

Masse brute

0,94

 kg

Degré de protection

IP 43

 

Boîtier

matière ABS

 

Interface de Communication

2×RS232, USB-A, USB-B, Ethernet, 4 IN / 4 OUT (numériques), Wi-Fi®

 

Alimentation

100 – 240 V AC 50/60 Hz

 

Alimentation optionnelle

accumulateur interne

 

Temps de travail avec l'alimentation d'accumulateur

5 heures

 

Nombre maximal d'échelons de légalisation

6000 e

 

Tension d'alimentation sur le transducteur tensometrique

0,4 µV

 

Pression maximale sur un échelon de légalisation

3,25 µV

 

Impédance minimale de transducteurs tensometriques

50 Ω

 

Impédance maximale de transducteurs tensometriques

1200 Ω

 

Tension d'alimentation sur le transducteur tensometrique

5V DC

 

Augmentation maximale de signal

39 mV

 

Connexion de senseurs tensometriques

4 ou 6 câble + écran

 

Température du travail

-10 – +40

 °C

Multi - étendue

Oui

 

Nombre maximal de plate-formes desservies

1

 

CE
2 ans de garantie

* en option

Films
Solution complète pour la mesure de la masse en pharma
Fonctions
Labelling

Labelling

Marking products with the right symbols contributes to quick and reliable identification. The balance/scale usually transfers product mass or product quantity to the label printer. The transferred value is printed with the following information: bar code, pictogram, content, address etc. In laboratory the labelling is performed in a semi-automatic mode, for industry in an automatic one (dynamic scales).
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Replaceable unit

Replaceable unit

Replaceable units.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.
Documentation
Cartes de produits
Data Sheet Data Sheet
Data Sheet

Voir
Voir
Download
Download

Choose more product:
Voir Voir DownloadDownload
Modes d'emploi
Mode d'emploi - CBCP 02
Mode d'emploi - CBCP 02
Voir
Voir
Download
Download
(0.25 MB)
Software Manual - Appendices 02
Software Manual - Appendices 02
Voir
Voir
Download
Download
(0.99 MB)
Start up Guide
Start up Guide
Voir
Voir
Download
Download
(3.15 MB)
Mode d'emploi - PUE C32
Mode d'emploi - PUE C32
Voir
Voir
Download
Download
(1.23 MB)
Déclarations de conformité
Conformity-Declaration
Conformity-Declaration
Voir
Voir
Download
Download
(0.12 MB)
Publications et brochures
Terminal de Balances PUE C32
Terminal de Balances PUE C32
Voir
Voir
Download
Download
(0.31 MB)
Software
Drivers

LabVIEW (3.05 MB)

RADWAG USB DRIVER 1.6.2 (1.25 MB)

Accessoires
R-LAB

Accessoires

Modules additionnels

RES Protocole de communication Radwag3

Newsletter

Inscrivez-vous à la Newsletter de RADWAG pour tout savoir sur nos nouveautés.

Voir plus
Radwag Balances Électroniques
Torunska 5
26-600 Radom
Poland
tel.: +48 48 386 60 00
e-mail: export@radwag.com
TIN: PL7960000327
Vimeo Radwag YouTube Radwag Facebook Radwag LinkedIn Radwag
© 2024 RADWAG Balances Électroniques. Tous les droits sont réservés.

Wybierz język

×
Change language AlbanianAlbanian
Change language DanishDanish
Change language NederlandseNederlandse
Change language EstonianEstonian
Change language FinnishFinnish
Change language HungarianHungarian
Change language IcelandicIcelandic
Change language KazakhKazakh
Change language LatvianLatvian
Change language LithuanianLithuanian
Change language MacedonianMacedonian
Change language NorwegianNorwegian
Change language PortuguesePortuguese
Change language RomanianRomanian
Change language RussianRussian
Change language SlovakSlovak
Change language SlovenianSlovenian
Change language SwedishSwedish
Change language UkrainianUkrainian
Change language SerbianSerbian
Change language MontenegrinMontenegrin
Change language page on Deutsch Deutsch
Change language page on English English
Change language page on Español Español
Change language page on Italiano Italiano
Change language page on Polski Polski
Change language page on Türkiye Türkiye
Česky
Português (Brasil)
Change website to USA USA
Change language page on 中文 中文
Presentations Presentations Presentations
Subscribe Subscribe Subscribe
Radwag in Facebook Radwag in Facebook Facebook
Radwag in YouTube Radwag in YouTube Youtube
Radwag in Vimeo Radwag in Vimeo Vimeo
Radwag in LinkedIn Radwag in LinkedIn LinkedIn
Webinars Radwag Webinars Radwag Webinars
close
E-mail:
Nom de l’entreprise :
Prénom:
I consent to the processing of my personal data for marketing purposes by Radwag Wagi Elektroniczne Witold Lewandowski.
I consent to receive marketing and product-related messages by electronic means from Radwag Wagi Elektroniczne Witold Lewandowski.
I have read the Privacy Policy of RADWAG Wagi Elektroniczne Witold Lewandowski.
lock_openI want to access the files
close
Slide to go back ↩